Mounting scientific evidence points to the indoor environment
as a major culprit for the high incidence of asthma cases
in the UK. Nick Warburton reports on how home improvements
can help relieve the suffering experience by millions
Current figures published by the National Asthma Campaign show
that one in seven children and one in 25 adults are asthmatic. Until
recently, it was assumed that vehicle exhaust fumes were a major
cause but scientific evidence has shown that even in the least polluted
parts of the UK, such as the Scottish Highlands, the proportion
of people with asthma is roughly the same as elsewhere in the country.
This means that areas with high pollution levels are unlikely to
be responsible for the increase in asthma cases.
Furthermore, considering that almost 80 per cent of our time is
spent indoors, the link between indoor pollution and asthma is becoming
far more conclusive. It is here that many common triggers can be
found, including: house dust mites; moulds, pollen and animal dander;
carbon monoxide and nitrogen dioxide from combustion products; household
products such as varnishes and paints; tobacco smoke; and pesticides.
Individuals can control some of these triggers by making changes
to their lifestyle, but in some cases EHOs are best placed to take
action.
Ian Ashmore, EHO at Swindon Council and a member of the CIEH's
Ad Hoc Asthma Group, has questioned whether the profession is doing
enough to protect public health (EHJ, January 1998, page 17). In
his article, Mr Ashmore argues that EHOs have little involvement
in managing and preventing asthma, even though they are in an ideal
position to help sufferers change their living environment. Research
has shown, for instance, that a major link between poor housing
conditions and asthma exists - dampness, poor ventilation and inadequate
heating are all major contributors to poor health. In May 2000,
a Nottingham-based charity National Energy Action (NEA), assisted
by the Nottingham Health Authority, published a study which found
that energy efficient homes with better ventilation can drastically
improve the health of asthma sufferers.
The NEA study, set up in 1998, focused on how improved insulation,
better heating systems and different types of ventilation could
make a significant difference to asthma sufferers. The research
was based around seven council houses in Nottingham, in which the
homes lacked full modern central heating systems and were occupied
by at least one asthmatic. Before any improvements were made to
the properties, a research team, led by Rob Howard from the NEA
and assisted by Roger Critchley from the Health and Housing Group
and Professor Tadj Oreszczn from University College, London, monitored
them for health, comfort, energy use, dust mite population, occupant
behaviour and physical conditions. The same tests were repeated
a year later to monitor the improvements.
Six of the homes chosen were low-rise traditional constructions
with solid or cavity brick walls. The exception was a Tarran bungalow
with concrete panel walls. As part of Nottingham City Council's
medical priority programme, the council upgraded all of the heating
systems in the houses. In the homes where there was only partial
heating, full heating was introduced. The houses with no central
heating at all were fitted with full heating systems. The heating
system consisted of a gas fan-flued boiler, an insulated hot water
cylinder with a thermostat, a room programmer, a room thermostat,
and one or two thermostatic radiator valves. In addition, loft insulation
was increased to a thickness of 200mm and any cavity walls in the
homes were insulated.
The rest of the study focused on improving ventilation and during
the course of the project three different ventilation strategies
were pilot tested. Two homes had "three quarter house"
mechanical ventilation and heat recovery systems installed. These
systems extracted moist air from the kitchen and bathroom and recovered
some of the heat. This heat was then used to warm fresh air from
outside which was supplied to all bedroom areas at the first floor.
(The systems chosen did not provide fresh air to ground floor living
rooms, which is why they are termed "three quarter house").
The systems also extracted moist air from the top of the staircase
to help reduce moisture entering the bedroom areas. The other houses
had humidity controlled extractor fans installed in the bathroom
and kitchen. Remote relative humidity sensors were also installed,
where necessary, to ensure the effectiveness of the fan.
A selection of homes also had individual heat recovery fans installed
in bedrooms. These fans extracted stale air, recovering some of
the heat and providing a small, but constant, stream of fresh air
back into the room. Although the research team experienced difficulties
installing the three ventilation systems, overall there were significant
health benefits. There was a dramatic reduction in the number of
dust mites in all but one of the houses monitored. The occupants
also benefited from noticeable health improvements. The study findings
showed that the health of all of the occupants had improved by 12
per cent. More importantly, the lung conditions of the four asthmatics
tested in the study had improved by an average of 20 per cent and
in three cases, the use of medication was reduced.
Commenting on the findings, Amanda Broatch of the National Asthma
Campaign pointed out: "Up to 85 per cent of children with asthma
are sensitive to dust mites. Good ventilation is likely to benefit
people with asthma because it reduces humidity, which in turn reduces
the number of house dust mites and moulds."
The study shows that positive health gains can be achieved cost
effectively - the total costs of improvements in the study ranged
from £700 to £5,500. However, as the study team reveal,
energy efficient measures alone are not sufficient. Appropriate
ventilation is also essential to maximise health improvements. The
group also believes that significant changes to national standards
(for ensuring adequate ventilation in existing homes) and a widening
of the scope of building regulations are essential. Since 1990,
it has been a statutory requirement for new homes to be equipped
with extractor fans, but most of Britain's houses are pre-second
world war and do not fall under this requirement.
There is clearly much more that can be done, but perhaps a good
starting place is for EHOs to acknowledge the problem of house dust
mites and their effect on health. According to Mr Critchley: "It
is important to make EHOs more aware of the problems of house dust
mites and the fact that they thrive in humid conditions. Getting
relative humidity levels down to 50 per cent would reduce moulds
and house dust mites dramatically." The DETR's proposed guidance
on the new Housing Health and Safety Rating System supports the
conclusions found in the NEA study - that the presence of house
dust mites is a hazard. This is a promising development, and means
that EHOs should be able to fulfil their role in protecting public
health. Any improvement on the current situation would be a breath
of fresh air.
A copy of the report The Nottingham Energy, Health and Housing
Study is available from First Report, 65 North Road, West Bridgford,
Nottingham, NG2 7NG, priced £6. Alternatively send a SAE for
a free four page leaflet describing the project and issues in more
detail. The National Asthma Campaign website can be accessed at: